Models
Power Supply
for BLS450, BLS900 and SLS Series

For operation of BLS450, BLS900 and SLS Series systems with AC power.

Power Supply
for BLS2000

For operation of BLS2000 systems with AC power.

Path Reduction Aperture for BLS450
to reduce path length down to 100 m

The Path Reduction Aperture is a set of special disks for the Transmitter and Receiver.

Path Reduction Aperture for BLS900
to reduce path length down to 100 m

The Path Reduction Aperture is a set of special disks for the Transmitter and Receiver.

Path Reduction Aperture for BLS2000
to reduce path length down to 500 m

The Path Reduction Aperture is a set of special disks for the Transmitter and Receiver.

Tripod standard, height 1.80 m

The tripod provides sturdy support for the Transmitter and Receiver of BLS and SLS Series.

Tripod high, height 3.00 m

The tripod provides sturdy support for the Transmitter and Receiver of BLS and SLS Series.

Mounting Screw for BLS/SLS

The Mounting Screw secures the Transmitter and Receiver of BLS and SLS Series to a stable platform

Direct Meteorological Data Input DMI-1
for BLS and SLS Series

The DMI-1 option consists of a temperature sensor, a barometric pressure sensor, a small tower and cables to connect the sensors to the SPU.

Direct Meteorological Data Input DMI-2
for SLS Series

The DMI-2 option consists of two temperature sensors, a barometric pressure sensor, a small tower and cables to connect the sensors to the SPU, the additional temperature sensor is to measure the temperature gradient.

Real-Time Heat Flux Extension
for SLS Series

The Real-Time Heat Flux Extension contains two temperature, pressure and a combined temperature and humidity sensors for an accurate calculation of CT2 and sensible heat flux for all - unstable and stable - conditions.

Real-Time Evapotranspiration Extension
for SLS Series

The Real-Time Evapotranspiration Extension contains net radiation, two soil heat flux, two temperature, pressure, precipitation, and a combined temperature and humidity sensors for determining the evapotranspiration in terms of latent heat through the so-called energy-balance method.

Real-Time Heat Flux Extension
for BLS Series

The Real-Time Heat Flux Extension contains two temperature, pressure, wind speed and direction, and a combined temperature and humidity sensors for an accurate calculation of CT2 and sensible heat flux for all - unstable and stable - conditions.

Real-Time Evapotranspiration Extension
for BLS Series

The Real-Time Evapotranspiration Extension contains net radiation, two soil heat flux, precipitation, two temperature, pressure and a combined temperature and humidity sensors for determining the evapotranspiration in terms of latent heat through the so-called energy-balance method.

Real-Time Basic Extension
for BLS and SLS Series

The Real-Time Basic Extension contains temperature, humidity, and pressure sensors for calculation of structure parameter of temperature and in the case of the SLS series also the dissipation rate of turbulent kinetic energy.

Real-Time Upgrade Aspirated Radiation Shield
for BLS and SLS Series

This set of two Aspirated Radiation Shields can be used with the Real-Time Heat Flux and Evapotranspiration Extensions for higher accuracy in temperature measurements.

Real-Time Sensor Interface Software
for BLS and SLS Series

The Real-Time Sensor Interface Software allows data from sensors from Real-Time Extensions or other weather stations connected to the Signal Processing Unit to be integrated into the SRun software.

Crosswind Extension SLSCW-1
for SLS Series

The Crosswind Extension allows of the horizontal wind speed component perpendicular to the optical propagation path.

Weather Station Port Cable, 30 m
for BLS and SLS Series

This optional cable can be plugged into the Weather Station Port of the Signal Processing Unit, it can be used to have the BLS or SLS measurement data transmitted in real-time to your equipment.

Analog Raw Signal Output Cable, 3 m
for BLS and SLS Series

The analog out cable with open wires is optionally available to connect the Analog Out Port of the Signal Processing Unit to an external datalogger or other signal processing equipment.